Index2 Fluke Series Pulse Oximeter Tester 
					The Index 2 is a lightweight, portable tool that includes preloaded manufacturers’ R-curves and the ability to define other “makes" for testing pulse oximeters. 
	Motion presets, player mode, transmission level control (TLC), and computer commands boost testing ability. The Index 2 can also be configured to include an optional electrical simulation feature with probe test. Optical and electrical simulations allow technicians to isolate problems quickly. The probe test identifies defective probes with quantitative test results. 
	 
	Features
	Portable
	Tenpreloaded manufacturers’ R-curves
	User-definable “makes for most other manufacturers
	R-curves for Masimo, Nonin and Philips Medical Systems (formerly Agilent / H-P) oximeters
	Six downloadable R-curve spaces available
	Simultaneous simulation of motion and arterial-oxygen levels
	Arterial wave-amplitude scale, calibrated in units of perfusion
	Tap/shiver motion simulations to explore the impact of motion
	RS-232 port for computer control
	Physiological finger
	 
	Electrical simulations with probe testing
	 
	
		
			| 
					
						
							| 
									
										
											
												
													
														
															| 
																	
																		
																			| Specifications |  
																			| O2 | 
																					
																						
																							| Range: | 35 % to 100 % |  
																							| Resolution: | 1 % |  
																							| Accuracy: | 100 % to 75 %: ± 1 % ± accuracy of the device under test; 74 % to 50 %: ± 3 % ± the accuracy of the device under test; < 50 % unspecified |  
																							| Repeatability: | Repeatability: ± 1 standard deviation |  |  
																			| Rate | 
																					
																						
																							| Range: | 30 BPM - 250 BPM |  
																							| Resolution: | 1 BPM |  
																							| Accuracy: | 1 % ± 1 BPM |  |  
																			| Pulse Amplitude | 
																					
																						
																							| Range: | 0 to 100 % of nominal pulse amplitude |  
																							| Resolution: | 1 % |  |  
																			| Probe test | 
																					
																						
																							| Continuity/Resistance: | Pulse amplitude is 20 % of maximum pass-through brightness |  
																							| Test Matrix: | Measures all combinations of possible interconnections in an XX point matrix |  
																							| Range: | 250 O to 150 kO |  
																							| Accuracy: | ± 5 % of reading |  |  
																			| LED/Detector voltage test | 
																					
																						
																							| Test Format: | Measures the voltage drop across Red LED, infrared LED, and the photo detector when the internally generated test signal is applied |  
																							| Test Signal: | Constant current source @ 1 mA |  
																							| Open Circuit: | 2.5 V max |  
																							| Measurement/Display Range: | 0 V to 4 V |  
																							| Accuracy: | ± 5 % of reading, 0.4 V to 4 V |  |  
																			| Dynamic Test | 
																					
																						
																							| Test Format: | Photodetector/diode response to both the red and infrared light generated by the probe when pulsed by an internal test signal |  
																							| Test Signal: | Pulsed between the two LEDs; constant current level @ 1 mA |  
																							| Test Results: | Nominal range of 0 to 2000 |  |  
																			| Checksum | 
																					
																						
																							|  | Sum of all locations in the program chip; for service use only |  |  
																			| General Information | 
																					
																						
																							| Display: | 2-line x 24-character super twist LCD |  
																							| Battery Life: | At least 4 hours of continuous use |  
																							| Battery Charger: | Lead acid battery charger only Input:100 V to 250 V, 50-60 Hz, 0.3 A
 Output:+12 V dc, 0.5 A
 |  
																							| Operating temperature: | 15 oC to 35 oC (59 oF to 95 oF) |  
																							| Storage temperature: | 0 oC to 50 oC (32 oF to 122 oF) |  
																							| Humidity | 10% to 90% non-condensing |  
																							| Dimensions (WxDxH): | 26.4 cm x 25.4 cm x 10.2 cm (10.4 in x 10 in x 4 in)
 |  
																							| Weight: | 2.38 kg (5 lb) |  |  |  |  | 
	
 
				
                
                
    Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.
    
    