Capnoxi® Plus Monitoring the patient’s respiratory status during CPR
Assists in determining when to intubate or extubate
Verification of ET tube placement Alerts if accidental extubation occurs
Verification of Ventilation during transport
Specialized date export function, help analyzing sleep condition
Monitoring SpO2, pulse rate, ETCO2 and respiratory rate;
Update 255 hour historical data replay on PC through USB
Equip Spo2 and Respiratory Status Analysis Software, comprehensive data analysis
Suitable for clinical and emergency circumstance
SpO2, SpO2+CO2 selectable
Software Function
Professional Data Analysis Software for CO2 Monitoring
Connecting the palm monitor to PC through USB
Storing Unlimited patients data
Displaying ETCO2,SPO2 Trends Table
Controlling PC printer, outputting trend graph, trend table report
Recording and storage object’s respiration details in clinical
Inside Pump Made by
Available types:
A- Capnoxi® plus with external sidestream CO2 sensor "Et7"
Inside Pump Made by
Available types:
A- Capnoxi® plus with external sidestream CO2 sensor "Et7"
B- Capnoxi® plus with External sidestream CO2 sensor "Et5"
C- Capnoxi® plus with built-in sidestream CO2 sensor (Internal Module)
D- Capnoxi® plus with external mainstream CO2
D- Capnoxi® plus with external mainstream CO2
TFT Screen
Type Colorful TFT LCD
Dimension 5.0 inch
LED
Patient Alarm Indicator Two colors:Yellow and Red
Sound Indicator
Loudspeaker Play alarm voices
Interfaces
Power 12VDC power socket*1pc
USB MINI USB socket*1
CO2
Principle NDIR single beam optics, dual wavelength, no moving parts.
Sample Rate 50mL/min, ±10mL/min
Initialization Time In 5 seconds,display the CO2 scan wave
Range CO2
0~99 mmHg
0~13 % Respiratory Rate
2~150 bpm
Resolution CO2
0.1 mmHg 0 ~ 40 mmHg
0.25 mmHg 40 ~ 99 mmHg
Respiratory Rate
1 bpm
Precision CO2
0~40 mmHg ±2 mmHg
40 ~99 mmHg ±5% of reading
Respiratory Rate
±1 bpm
Apnea Alarm Time 10~60s
SpO2
SpO2
Measure Range
SpO2 0 - 100 %
Pulse rate 35 - 254 BPM
Measure Accuracy
SpO2 ±2% (70 - 100%)
Pulse rate :±2 or ±2 BPM
Battery
Quantity 4
Model Rechargeable lithium battery
Voltage 3.7 V
Capacity 2200mAh
Working time 10 hours
Recharging time 4 Hours
Standard:
CO2 Sample Line ......... 1Pcs
Nasal Tube .................. 1PcsPower Adapter .............. 1Pcs
Water-trap Column ......... 1Pcs
Airway Adapter ............. 1Pcs
Options:
Product Features
Monitoring SpO2, pulse rate, ETCO2 and respiratory rate;
Update 255 hour historical data replay on PC through USB
Equip Spo2 and Respiratory Status Analysis Software, comprehensive data analysis
Suitable for clinical and emergency circumstance
SpO2, SpO2+CO2 selectable
Software Function
Professional Data Analysis Software for CO2 Monitoring
Connecting the palm monitor to PC through USB
Storing Unlimited patients data
Displaying ETCO2,SPO2 Trends Table
Controlling PC printer, outputting trend graph, trend table report
Recording and storage object’s respiration details in clinical
Inside Pump Made by
Available types:
A- Capnoxi® plus with external sidestream CO2 sensor "Et7"
Inside Pump Made by
Available types:
A- Capnoxi® plus with external sidestream CO2 sensor "Et7"
B- Capnoxi® plus with External sidestream CO2 sensor "Et5"
C- Capnoxi® plus with built-in sidestream CO2 sensor (Internal Module)
D- Capnoxi® plus with external mainstream CO2
D- Capnoxi® plus with external mainstream CO2