MD06x
MD06x Advanced blood pressure with Oximetry,
3 users data record and alarm setting,
Meditech 06X have a large color screen, and come with PC software to Show trend graph,
analytical diagrams Edit add notes to every piece of data by connecting the device with PC through USB port.


MD06x Advanced blood pressure with Oximetry,
3 users data record and alarm setting,
Meditech 06X have a large color screen, and come with PC software to Show trend graph,
analytical diagrams Edit add notes to every piece of data by connecting the device with PC through USB port.


Read More
2.8" TFT color screen 320x240 pixels
NIBP measurement
SpO2 measurement
Trusted accuracy clinically validated
Oscillometry with step deflation
Multi-user mode (Adult Child New born)
Built-in flash memory up to 100 items for each user (3 User)
Built-in BP Alarms
Automatic cuff inflation and deflation
Reliable power supply with or AA battery
Battery status indicator
Data Review: List and Trend
Setting for Time .Date .mHg/kPa .Alarm .User type .Language
Sync with PC-based Software via USB port accurate analysis systems
 



 

 
Comes with PC Software for data transfer
Show trend graph analytical diagrams Edit add notes to every piece of data 
Edit examinees information medical advices condition descriptions present drug usage info etc. 
Print report support print preview
 
06X Soft


Measurement Accuracy
SpO2 70%~100%    ±2%
0%~69%      undefined
PR ±2bpm or ±2% (select larger) 
Measurement Performance In Weak Filling Condition
pulse-filling ratio : 0.4% SpO2 error ±4%
pulse rate error ±2bpm or ±2% (select larger)
Optical Sensor
Red light wavelength is 660nm 6.65mW
Infrared wavelength is 880nm 6.75mW  
Display 2.8'' color LCD Display
 
NIBP Specifications
Measurement Method Oscillometric method

Working modes Automatic
Measurement Range Pressure adult 0~290mmHg(0~38.6kPa)
pediatric 0~235mmHg(0~31.3kPa)
neonatal 0~140mmHg(0~18.6kPa)
Pulse: 40~240/min
Inflation adult 160mmHg
pediatric 120mmHg
neonatal 70mmHg
Alarm Range adult mode SYS ALM: 40~270 mmHg 
DIA ALM: 10~215 mmHg
pediatric mode SYS ALM: 40~200 mmHg
DIA ALM: 10~150 mmHg
neonatal mode SYS ALM: 40~135 mmHg
DIA ALM: 10~100 mmHg
Overpressure protect adult mode 295±5mmHg
pediatric mode 240±5mmHg
neonatal mode 145±5mmHg

Resolution
Pressure 1mmHg

Measurement Accuracy
Cuff Pressure Accuracy ±3mmHg
Error The BP Value of the device is equivalence with the measurement value of Stethoscopy. The error meets all the conditions in the YY0667-2008.
Operating Temperature/ Humidity +5oC~40 oC      .  15%RH~80%RH
Transport and Storage Temperature/Humidity -20oC~+55oC     .  ≤95%RH
Atmospheric pressure 80kPa~105kPa
Battery 4 "AA" alkaline batteries AC Adapter separately sold
Main Unit Dimensions 130(L)*110(W)*80mm(H)  
Main Unit Weight 300gram
 

Product Features

    2.8" TFT color screen 320x240 pixels
    NIBP measurement
    SpO2 measurement
    Trusted accuracy clinically validated
    Oscillometry with step deflation
    Multi-user mode (Adult Child New born)
    Built-in flash memory up to 100 items for each user (3 User)
    Built-in BP Alarms
    Automatic cuff inflation and deflation
    Reliable power supply with or AA battery
    Battery status indicator
    Data Review: List and Trend
    Setting for Time .Date .mHg/kPa .Alarm .User type .Language
    Sync with PC-based Software via USB port accurate analysis systems
     



     

     
    Comes with PC Software for data transfer
    Show trend graph analytical diagrams Edit add notes to every piece of data 
    Edit examinees information medical advices condition descriptions present drug usage info etc. 
    Print report support print preview
     
    06X Soft


Product Specifications

    Measurement Accuracy
    SpO2 70%~100%    ±2%
    0%~69%      undefined
    PR ±2bpm or ±2% (select larger) 
    Measurement Performance In Weak Filling Condition
    pulse-filling ratio : 0.4% SpO2 error ±4%
    pulse rate error ±2bpm or ±2% (select larger)
    Optical Sensor
    Red light wavelength is 660nm 6.65mW
    Infrared wavelength is 880nm 6.75mW  
    Display 2.8'' color LCD Display
     
    NIBP Specifications
    Measurement Method Oscillometric method

    Working modes Automatic
    Measurement Range Pressure adult 0~290mmHg(0~38.6kPa)
    pediatric 0~235mmHg(0~31.3kPa)
    neonatal 0~140mmHg(0~18.6kPa)
    Pulse: 40~240/min
    Inflation adult 160mmHg
    pediatric 120mmHg
    neonatal 70mmHg
    Alarm Range adult mode SYS ALM: 40~270 mmHg 
    DIA ALM: 10~215 mmHg
    pediatric mode SYS ALM: 40~200 mmHg
    DIA ALM: 10~150 mmHg
    neonatal mode SYS ALM: 40~135 mmHg
    DIA ALM: 10~100 mmHg
    Overpressure protect adult mode 295±5mmHg
    pediatric mode 240±5mmHg
    neonatal mode 145±5mmHg

    Resolution
    Pressure 1mmHg

    Measurement Accuracy
    Cuff Pressure Accuracy ±3mmHg
    Error The BP Value of the device is equivalence with the measurement value of Stethoscopy. The error meets all the conditions in the YY0667-2008.
    Operating Temperature/ Humidity +5oC~40 oC      .  15%RH~80%RH
    Transport and Storage Temperature/Humidity -20oC~+55oC     .  ≤95%RH
    Atmospheric pressure 80kPa~105kPa
    Battery 4 "AA" alkaline batteries AC Adapter separately sold
    Main Unit Dimensions 130(L)*110(W)*80mm(H)  
    Main Unit Weight 300gram
     