• MD09x smart monitor
  • MD09x smart monitor
  • MD09x smart monitor
  • MD09x smart monitor
MD09X wrist multi-parameters and individual parameter patient monitor.
The smart multi-parameters patient monitor with a small size can simultaneously measure the ECG, Heart rate, Respiration, Blood pressure, SpO2 and Pulse rate.
It can respectively measure the Blood pressure, SpO2 or the both. 

MD09x patient monitor Workable with smart device app (Android and iOs)

Product Features

    2.4 inch TFT color screen . Resolution: 320*240
    Display waveform:  2 channels waveform of ECG, respiration, blood pressure and SpO2 can be both displayed
    ECG: With the function of abnormal data store, daily data store and trend display 
    ECG Cable: 3 leads .10 Leads
    NIBP: Manual measurement. Automatically identify the adult and child. System can adjust the maximal pressure for adult and child. The blood pressure waveform can be displayed in real-time
    SpO2: Anti-low per-fusion and motion artifact
    Trend display: Display the trend of ECG, blood pressure, SpO2, ST segments, premature and respiration in 96 hours
    Alarm modes: Visible alarming reminder and speaking voice alarming reminder
    Wireless:  Bluetooth 4.0
    E-Manual: Embedded e-manual for self reading
    workable with smart devices (Android &iOs)




    Options
    Bluetooth printer
     

Product Specifications

    ECG
    ECG waveform gain:              0.5 mm / mV,1.0 mm / mV, 2.0 mm / mV
    Scanning speed :                   7.5mm / s, 15mm / s    
    Heart rate and alarm range :      
    Adult:                                    30 bpm ~250 bpm (beats / min)
    Precision of ECG:                 ±5%
    Resolution:                           1 bpm (Times/Minute)
    Sensitivity:                            >200uV (Peak-to-Peak Value)
    Trigger level threshold:          200nV (Lead II)
    Resistance of differential input:     >5MΩ
    Common-mode rejection ratio :     ≥ 90 dB
    Electrode polarization voltage range: 300mV
    Leakage current:                          <10uA
    Input signal range:                         ±5mV
    ECG abnormal types:Tachycardia, Bradycardia, VPC, Bigeminal rhythm, Trigeminal rhythm, RonT, VTAC, Escape Beat and Sinus arrest.
    Alarm:The voice audible alarm and screen visual alarm display dual alarm, under review.
    Heart rate alarm range:         30~250 bpm
    Alarm Mute:                           Less than 10 seconds
    Alarm sound pressure:          45 to 65 db
    Frequency response :      
                Flter :                           0.67 Hz ~ 40Hz
                Guardianship :             0.05 Hz~40Hz
                Detection:                    0.05 Hz~100Hz
    Calibration signal :                   6 mm / mV
    ST segment measurement:
    Measured range:                    -2.0mV~+2.0mV
    Precise:                                  -0.8mV~+0.8mV; ±0.02mV or±10%
    Renew period:                         10s
    Pacing pulse suppression :    
                Range:                        ± 2mV to 500Mv
                Width:                         0.1ms ~ 2ms
               Rise time:                    10us ~ 100 μs
    Inhibition of the pacing pulse detector for fast ECG signal :   2.5V/s
    Can inhibit the T-wave amplitude: > 5mV
     
    Noninvasive blood pressure (NIBP)
    Measurement:                     Oscillometric pressure when the blood pressure measurement.
    Pressurized automatic calibration zero
    Measuring range :                 30mmHg~280mmHg
    Measurement accuracy :       ±5mmHgor ±5%
    Maximum cuff pressure:        Cuff pressure does not exceed 300 mmHg,
                                                  The cuff pressure at 15 mmHg or more time is not more than 3min.
    Overvoltage protection:          Yes
    Alarm:                                  Systolic / diastolic alarm error of ± 2 mmHg
                                                   Atrial premature function
    Measuring wrist Week            135mm ~ 215mm
     
    Oxygen saturation (SpO2)
    Measuring range :               40% ~ 99%
    Measurement accuracy:        90% ~ 99% Tolerance ± 2%
                                                   70% ~ 89% Tolerance ± 4%
                                                  40% ~ 69% Tolerance ± 6%
    Alarm range :                      50% ~ 99%
     
    Pulse rate
    Measuring range  :             30 Beats / min ~ 80 Beats / min ± 2 
                                                  80 Beats / min ~150 Beats / min ± 4 
                                                 150 Beats / min ~240 Beats / min ,± 5  
    Measurement accuracy:    ± 5%

    Resist electric shock :         CF type
    Build-in :                                3.7V 1000mh
    Power adapter:                   5V/1A 2W battery charger:
    Power                                    2W
    Type :                                    Non-AP / APG type  Do not prevent inlet device
    Work environment:
    Temperature:                         5 ℃~40 ℃
    Humidity:                               15% ~80%
    Atmospheric pressure:           80kPa ~105kPa
    Storage environment:
    Temperature :                      -20 ℃ ~55℃
    Humidity :                            10%~90%
    Atmospheric pressure :       50.0 kPa ~106.0kPa

    Size and Weight
    Dimensions :                    7cm (W) × 7cm (H) ×2.6cm (D) (does not include a wrist strap)
    Net Weight :                     130g
    Gross Weight                      0.5Kg
     

Related Accessories

    Standard:

    ECG Cable (3 Leads) ...... 1Pcs
    SpO2 probe (Soft tip)   ..... 1Pcs
    Power Adapter    .............. 1Pcs
    Cleaning Cloth  ................ 1Pcs

    Options:

    ECG Cable (10 Leads)
     

Related Products

Promoted Products

Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Legal notice Terms and conditions Cookie policy Privacy Policy Professional organisations Careers

2024© Copyright احدى فروع شركة ميديتك جروب و المركز الرئيسي الإقليمي لمنطقتي الشرق الأوسط و شمال إفريقيا | Meditech Group (Middle East branch).

Meditech Group

To Top