Patient monitor 12inch TFT. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends,
Up to10000 pieces of NIBP record storage,

Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated;

Product Features

    High resolution 12” color TFT display
    12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
    Light weight, compact and portable
    Built-in rechargeable lithium battery 
    Unique human voice alarm
    Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
    Powerful storage: Maximum 720 Hour graphic and tabular trends of all
    parameters, up to 10000 NIBP review ,200alarm review ,2Hours of all waveforms
    System software can be upgraded through network
    Data and waveforms color be adjustable
    Arrhythmia analysis and S-T segment analysis
    Suitable for adult, paediatric and neonatal patient




    Options 
    Invasive Blood Pressure (IBP)
    Carbon dioxide (CO2) Module
    Thermal Printer
    Touch Screen

    Built-in Wifi (MD9012)









Product Specifications

    ECG 
    Lead Mode                   5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
    Lead selection              I, II, III, avR, avL, avF, V, 
    Waveform                     2 ch 
    Lead mode                   3 Leads ( R, L, F or RA, LA, LL)
    Lead selection              I, II, III, 
    Waveform                    1 ch 
    Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV,  auto 
    HR and Alarm  
          Range 
          Adult                     15 ~ 300 bpm
          Neo/Ped               15 ~ 350 bpm
          Accuracy               ± 1% or ± 1bpm,which great
          Resolution            1 bpm
         Sensitivity              > 200 (uV ) 
    Differential Input Impedance  > 5 MΩ
    CMRR
          Monitor                 > 105 dB 
         Operation              > 105 dB
         Diagnosis              > 85 dB
    Electrode offset potential  ±300mV
    Leakage Current       < 10 uA
    Baseline Recovery    < 3 S  After Defi.
    ECG Signal Range     ±8 m V ( Vp-p ) 
    Bandwidth    
         Surgery                 1 ~ 15 Hz
         Monitor                  0.5 ~ 35 Hz
         Diagnostic             0.05 ~ 100 Hz
    Calibration Signal    1 (mV ),  Accuracy :±5%  
    ST Segment Monitoring Range   
    Measure and Alarm -2.0 ~ +2.0 mV
    ARR Detecting  
    Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC 
        Alarm     Available
        Review    Available 

    RESPARATION 
    Method      Impedance between R-F(RA-LL)
    Differential Input Impedance    >2.5 MΩ
    Measuring Impedance Range:  0.3~5.0Ω
    Base line Impedance Range:    0 – 2.5  KΩ
    Bandwidth     0.3 ~ 2.5 Hz
    Resp. Rate 
    Measuring and Alarm Range 
         Adult                0 ~ 120 rpm
         Neo/Ped          0 ~ 150 rpm 
    Resolution                      1 rpm
    Accuracy                      ±2 rpm 
    Apean Alarm            10 ~ 40 S 

    NIBP 
    Method                Oscillometric
    Mode        Manual, Auto, STAT
    Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
    Measuring Period in STAT Mode 5 Min
    Pulse Rate Range    40 ~ 240 bpm
    Alarm Type            SYS, DIA, MEAN
    Measuring and alarm range    
    Adult Mode
                 SYS   40 ~ 270 mmHg
                 DIA    10 ~ 215 mmHg
                 MEAN  20 ~ 235 mmHg 
    Pediatric Mode
                 SYS   40 ~ 200 mmHg
                 DIA    10 ~ 150 mmHg 
                 MEAN  20 ~ 165 mmHg
    Neonatal Mode 
                 SYS   40 ~ 135 mmHg
                 DIA    10 ~ 100 mmHg
                 MEAN   20 ~ 110 mmHg 
    Resolution 
                  Pressure    1mmHg
                  Accuracy
                  Pressure  
    Maximum Mean error     ±5mmHg
    Maximum Standard deviation  ±8mmHg 
    Overpressure Protection
                 Adult Mode        297±3 mmHg 
                 Pediatric Mode  240±3 mmHg
                 Neonatal Mode  147±3 mmHg 

    SpO2 
    Measuring Range          0 ~ 100 %
    Alarm Range                 0 ~ 100 %
    Resolution                     1 %
    Accuracy                      70% ~ 100%  ±2 %
                                         0%  ~  69%  unspecified
    Actualization interval   about 1 Sec.
    Alarm Delay                  10 Sec. 
    Pulse Rate 
    Measuring and Alarm Range  0~254bpm
    Resolution                        1bpm 
     Accuracy                         ±2bpm 

    TEMPERATURE 
    Channel      1
    Measuring and Alarm Range  0 ~ 50  C
    Resolution                          0.1~C
    Accuracy                          ±0.1~C 
    Actualization interval about 1 Sec.
    Average Time Constant   < 10 Sec. 

    IBP 
    Label      ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range 
        ART                           0 ~ 300 mmHg
        PA                             -6 ~ 120 mmHg
        CVP/RAP/LAP/ICP  -10 ~ 40 mmHg
        P1/P2                       -10 ~ 300 mmHg     
    Press Sensor 
    Sensitivity                      5  uV/V/mmHg 
       Impedance                 300-3000Ω
       Resolution                    1 mmHg 
       Accuracy      ±2% or ±1mmHg, which great about 1 Sec. 
     

Related Products

Promoted Products

Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Legal notice Terms and conditions Cookie policy Privacy Policy Professional organisations Careers

2024© Copyright احدى فروع شركة ميديتك جروب و المركز الرئيسي الإقليمي لمنطقتي الشرق الأوسط و شمال إفريقيا | Meditech Group (Middle East branch).

Meditech Group

To Top